The SmartUnit

Long Term Satisfaction!

 

The variable speed SMARTUnit is a versatile refrigeration system integrated within a compact housing and is used for smaller surface commercial refrigeration.

 

Application:

  • Golf clubs, ski resorts, pharmacies, convenience stores, restaurants, florists, laboratories, wine cellars and other applications requiring a refrigeration capacity below 20 kW.

Advantages:

  • Better control of ambient humidity and temperature of refrigerated products.
  • Reduction of energy costs
  • Reduction of sound and vibration related to compressor operation
  • Insured long term compressor protection
  • Rapid and economical remote management
  • Turnkey condensing unit

Mechanical & Electrical Options:

  • Variable speed compressor and condenser fan
  • Electric and electronic controls


SMART UNIT CAPACITY
VARIABLE SPEED MEDIUM
TEMPERATURE R-404A

Compressor
Model
Ambient
Temperature ºF
Suction Temperature ºF
(capacity MBH)
Connexion Size Receiver
(lbs)
Operating Charge
(lbs)
    0 5 10 15 20 25 30 Succion Liquide Std Opt Summer Winter
UNT3HPVAR-2
H300CC
90 19,7 22,7 25,8 29,3 32,8 36,9 41,1            
95 18,5 21,2 24,2 27,4 30,8 34,8 38,7 1 1/8 1/2 24 51 6,2 13
100 17,3 19,8 22,6 25,6 28,8 32,5 36,2            
105 16,1 18,4 21,1 23,9 26,9 30,4 33,8            
UNT5HPVAR-2/5
H603CC
90 33,4 37,9 42,9 49,4 54,1 60,7 67,3            
95 31,5 35,9 40,6 45,8 51,2 57,5 63,8 1 3/8 5/8 24 51 9,2 19
100 29,7 33,8 38,3 43,2 48,4 54,3 60,4            
105 27,8 31,7 36,0 40,7 45,5 51,2 56,9            
UNT7.5HPVAR-2/5
K750CC
90 50,9 57,4 64,6 72,4 80,4 89,8 99,2            
95 47,9 54,1 60,8 68,2 75,8 84,6 93,5 1 3/8 5/8 51 51 11 24
100 45,0 50,8 57,2 64,0 71,2 79,5 87,9            
105 42,1 47,5 53,5 59,9 66,6 74,5 82,4            
UNT10HPVAR-2/5
K1000CC
90 60,5 68,8 77,8 87,6 97,8 109,6 121,5            
95 56,8 64,7 73,2 82,5 92,1 103,3 114,6 1 3/8 7/8 51 68 13 29
100 53,1 60,6 68,7 77,4 85,6 97,1 107,7            
105 49,4 56,5 64,1 72,4 80,9 90,9 100,9            
UNT15HPVAR-2/5
K1500CC
90 81,5 91,8 103,1 115,3 127,9 142,6 157,4            
95 77,4 87,3 98,2 109,8 122,1 136,1 150,4 1 5/8 7/8 68 125 15 33
100 73,2 81,7 93,1 104,3 115,9 129,5 143,1            
105 68,7 77,9 87,8 98,5 109,7 122,5 135,5            

Notes :

  1. Multiply by 0.5 to obtain minimum charge.
  2. Charge of the receiver (lbs) is based at 90% full for 90ºF.
  3. Refrigerant operating charge is based at 30% liquid and 70% vapour in summer, and at 70% liquid and 30% vapour in winter.


SMART UNIT ELECTRICAL DATA
VARIABLE SPEED MEDIUM
TEMPERATURE R-404A

Model Voltage Compressor Condenser fan motor MCA MOP Breaker Amp.
    Model Qty RLA Qty HP FLA      
UNT3HPVAR-2 208-240/3/60 H300CC 1 19,6 1 1/2 2,9 27,4 50 60
UNT5HPVAR-2 UNT5HPVAR-5 208-240/3/60 575/3/60 H503CC H503CC 1 29,1 16,5 1
1
1/2 1/2 2,9 1,3 38,0 21,9 70
30
60
30
UNT7.5HPVAR-2 UNT7.5HPVAR-5 208-240/3/60 575/3/60 K750CC K750CC 1 36,3 21,3 2
2
1/2 1/2 2,9 1,3 51,2 29,2 90
50
60
60
UNT10HPVAR-2 UNT10HPVAR-5 208-240/3/60 575/3/60 K1000CC K1000CC 1 43,2 25,5 2
2
1/2 1/2 2,9 1,3 59,8 34,5 100 50 100
60
UNT15HPVAR-2 UNT15HPVAR-5 208-240/3/60 575/3/60 K1500CC K1500CC 1 68,4 40,1 3
3
1/2 1/2 2,9 1,3 94,2 54,7 160 90 150
60

Ask us how the variable speed SMARTUnit can improve your company’s energy performance.